Home / Products / Marine HVAC Systems / Marine Chiller Systems
COOLMAR CHILLED-WATER SYSTEMS
Marine Chiller Systems for Multi-Zone Vessel Air Conditioning
Coolmar offers compact, modular and inverter marine chiller routes for chilled-water HVAC systems. ERBA Marine reviews the vessel cooling load, redundancy, electrical supply, seawater circuit, chilled-water distribution and machinery-space constraints before quotation.
Final capacity, compressor arrangement, voltage, refrigerant and protection package are confirmed for the project.
Compact, modular and inverter chillers
Chilled-water generation coordinated with fan coils, pumps, controls and vessel interfaces.
Authorized GCC Dealer
Coolmar product selection and supply coordinated by ERBA Marine.
Project-Led Review
Loads, utilities, space and interfaces checked from verified data.
Newbuild & Retrofit
Support for planned projects, refits and replacement scopes.
Current Configuration
Specifications and warranty terms confirmed in quotation.
Authorized Coolmar dealer for the GCC
ERBA Marine manages regional product selection, technical clarification, quotation and supply for Coolmar marine HVAC and refrigeration equipment.
CHILLER FORMATS
Choose the closest chilled-water architecture.
The final selection follows the vessel load profile, installation space, redundancy requirement and electrical system.
Compact Chillers
Single-frame equipment for projects where a compact packaged arrangement suits the machinery space.
- Project-matched capacity
- Seawater and chilled-water flow reviewed
- Service access confirmed
Modular Chillers
Multiple modules can support staged capacity, access and redundancy objectives.
- Staged or redundant operation
- Module access and lifting route checked
- Controls and hydraulic layout coordinated
Inverter Chillers
Variable-speed chiller solutions for projects requiring closer part-load control.
- Load profile reviewed
- Generator and electrical system checked
- Current model range confirmed at quotation
PUBLISHED CONSTRUCTION
Marine materials and protective controls support the chiller package.
Coolmar publishes stainless plate heat exchangers, 304 chrome-nickel bodies and fasteners, copper-nickel condensers, pressure protection, water-flow monitoring and freeze protection. The exact configuration is model- and project-specific.
Water circuits
Both sides of the chiller must be sized and arranged correctly.
- Seawater temperature and flow
- Chilled-water supply and return
- Pumps, expansion and balancing
Electrical and controls
Starting demand, staging and controls must suit the vessel power system.
- Voltage, phase and frequency
- Available generator capacity
- Staging, redundancy and alarms
TECHNICAL ENQUIRY CHECKLIST
What to send for a useful HVAC review.
Complete operating, load and interface information reduces unnecessary clarification and helps ERBA Marine prepare a more accurate technical and commercial response.
Vessel, spaces & duty
- Vessel type, length, duty and operating region
- Calculated peak and typical cooling loads
- Required chilled-water temperatures
- Available voltage, phase, frequency and generator capacity
- Design ambient-air and seawater temperatures
- Seawater pump, strainer and discharge arrangement
Utilities, interfaces & drawings
- Chilled-water pipework, pumps and expansion arrangement
- Number and capacity of fan-coil zones
- Redundancy, staging and part-load requirements
- Machinery-space dimensions, access and lifting route
- Control, alarm, class and documentation requirements
- General arrangement and HVAC schematics
PROJECT PROCESS
A clear route from HVAC enquiry to coordinated supply.
Marine HVAC selection benefits from documented loads, design conditions and interface checkpoints.
PROCESS
1. Send the project data
Share the vessel, spaces, duty, design conditions, utilities, drawings and required scope.
PROCESS
2. Clarify the interfaces
ERBA Marine identifies missing inputs and checks capacity, space, air, water and electrical interfaces.
PROCESS
3. Confirm the proposal
Configuration, current specifications, documentation, warranty terms, price and delivery are agreed.
PROCESS
4. Coordinate supply
ERBA Marine remains the customer-facing contact through the confirmed supply scope.
Important: Published ranges and examples are selection guidance. Final capacity, dimensions, voltage, refrigerant, materials, controls, documentation, warranty terms, price and delivery are confirmed only in ERBA Marine’s written quotation.
FREQUENTLY ASKED QUESTIONS
Marine Chiller Systems FAQs
Practical answers for selection, replacement and project planning.
A compact chiller is arranged as one packaged frame. A modular system uses multiple modules, which can support staged capacity, access or redundancy objectives when the project layout allows.
An inverter system may be considered where the load varies and closer part-load control is valuable. The vessel electrical system, operating profile and required capacity range must be reviewed.
Yes. ERBA Marine can review the chiller, fan coils and related controls as a coordinated supply scope when the chilled-water system data is provided.
Not necessarily. Published features describe Coolmar’s chiller range, but the exact heat exchangers, controls, protection devices, materials and refrigerant are confirmed for the selected configuration.
Send the cooling load, voltage, design seawater temperature, chilled-water conditions, redundancy requirement, machinery-space dimensions and available drawings.
PROJECT-SPECIFIC ENQUIRY
Request a Marine Chiller Systems review from ERBA Marine.
Send the strongest available load, space, utility and interface information. ERBA Marine will review the requirement and identify missing data before quotation.
- Attach HVAC drawings, schedules and clear photographs.
- State design air and seawater conditions.
- Confirm voltage, phase, frequency and available space.
- Final scope is confirmed in writing before supply.
Send Chiller Project Data
Fields marked * are required. HVAC drawings, equipment schedules and photographs are strongly recommended.
Your technical and contact information is sent only to ERBA Marine’s website enquiry recipients for follow-up.